Main camp product:Carbon Black Content ApparatusAbrasion Resistance TesterResistance To Pinch TesterCyclic bending TesterThermal stability testHorizontal Flame TesterAir Or Oxygen Ageing TesterVW-1 Flame TesterWire Wearing TesterFLEXIBLE CABLE FLEXING TESTERCONDUCTOR ELONGATION TESTERSmoke-density TesterTemperature Rising TesterUL94 FLAME CHAMBER TESTERGLOW WIRE TEST APPARATUS
Product Material
[

Calibrating Device for Spark Tester

]
sendmsg
Product Name: Calibrating Device for Spark Tester
Product Model:
Manufacturer: other brand
file:No Related Documents


Product Description

JN-LMD-3048 Calibrating Device for Spark Tester According to EN50356:2002, PM451E/PM452E 2007-02-01,GB/T3048.9 and GB/T3048.15 GB/T26873-2011,JB/T4278.10-2011 wire and cable spark test method, it is used to detect the minimum sensitivity and stability of the spark tester special equipment.

Calibrating Device for Spark Tester

JN-LMD-3048 Calibrating Device for Spark Tester

This device is designed according to standards of EN50356:2002、

PM 451E/PM 452 E 2007-02-01: Test Instruction for the Factory

Surveillance of Rubber-insulated Cables according to DIN VDE

0282 Part 1 and GB/T3048.9、GB/T3048.15 、GB\T 26873-2011 to detect the sensitivity and stability of spark tester.

1、A usual construction of a failure simulator has a needle tip and a metal plate or a metal base (shoe).

2、One of these elements has been mounted on the rotating spindle while the other one has been fixed that during the turn of the spindle a discharge distance develops.

3、The discharge distance between tip and plate has to be fixed to (0,25 ± 0,05) mm.

4、The measurements of the plate and turning speed have to be chosen in that way that there is a gap for the requested maximum period of 0,025 s (at AC) or 0,000 5 s (at DC) having a maximum repetition rate of 1 s.

5、The needle tip is formed, from a chromium-plated steel element having a diameter of 1,0 mm and an axis length of 3,75 mm. The radius of the tip is smaller or equal to 0,03 mm.

6、The peak angle is not above 16°.

Calibrating Device for Spark Tester\Calibrating Device for Spark Tester\Calibrating Device for Spark Tester\Calibrating Device for Spark Tester\Calibrating Device for Spark Tester



Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!


Calibrating Device for Spark Tester

More Products
Product Search
Contact Us
Browse by Category
Copyright@ 2003-2025   Dongguan Jen Test Equipment Co., Ltd.   粤ICP备09054376号