Gold Karat Tester Model MK-300

]
sendmsg
Product Name: Gold Karat Tester Model MK-300
Product Model: Mk-300
Manufacturer: JENTEST
Product file: No Related Documents


Product Description

Gold Karat Tester Model MK-300:1、Can show directly the karat、density of Gold and purity%、density of platinum and density of the other metals.2、Can distinguish between the real precious metal and the f

Gold Karat Tester Model MK-300

   Detail
Gold Karat Tester Model MK-300
 
It can shows KaratDensity of Gold and Purity%Density of Platinum
Function:
1、Can show directly the karatdensity of Gold and purity%density of platinum and density of the other metals.
2、Can distinguish between the real precious metal and the fake metal.
3、No more stains and scratches left on your gold after testing.
4、Only 10 seconds to measure karatdensity of gold and purity%density of platinum(Pt)
5、Can not measure when a sample has air hole and with set stones for metal pieces
6、Based on the marketing demand, a special  software was designed. After measuring, the result will be showed, seen as :HI” or “LO”. The display shows “HI” when the value of >upper limit, the display shows “LO” when the value<lower limit. The value of upper limit and lower limit are set by user.
7、Can be set the ratio of copper to silver by user. Such as ,7364 and 5:5.
MODEL
MK-300
MK-1500
MEASURING RANGE
0.01~ 300g
0.01 ~ 1500g
MEASURABLE RANGE
5 ~ 300g
10 ~ 1500g
AVERAGE WEIGHT RESOLUTION
0.001g
DENSITY RESOLUTION:
0.001g/cm3
SETTING
WATER TRMPERATURE COMPENSATE SETUPSOLUTION COMPENSATE SETUP
FUNCTION
IT CAN SHOWS KARATDENSITY OF GOLD AND PURITY%DENSITY OF PLATINUM
GOLD
DISPLAY VALUE
KARAT AND DENSITY
KARAT’S RANGE PROPORTION
IT CAN SET THE GOLD KARAT’S HIGH LIMIT AND LIW LIMIT,SUCH AS:5K~24k6k~24K
PARAMETER SETUP
IT CAN BE SET OUT THE RATIO OF COPPER TO SILVER IN GOLD SUCH AS7364 AND 5:5 BY USER
PLATINUM
DISPLAY VALUE
PURITY%DENSITY OF PLATINUM
PT’S RANGE
IT CAM SET THE PLATINUMS HIGH LIMIT AND LOW LIMITSACH AS1000K~600K1000K~500K
PURITY SET
IT CAN SET PLATINUM ALLOY WITH DIFFERENT METAL PARAMETER
CONNECTION INTERFACE
RS-232
WEIGHT / DIMENSIONS
1.54kg / 218 x 190 x 170mm
5.50kg / 317 x 210 x 235mm

Gold Karat Tester-Comparison between MK-300 VS GK-300 OR MK-1500 VS GK-300

MODEL

Specification

MK-300

GK-300

 

 

 

Maximum weighing

300g

300g

Measurable range

5~300g

5~300g

Weighing precision

0.01g

0.01g

Average weight

0.001g

No

S.G. precision

0.001 g/cm3

   0.1 or0.01g/cm3

Water temperature compensate setup

Yes

Yes

Solution compensate setup

Yes

Yes

Gold

Display value

Karat  DensityPt

KaratDensity Pt

Karat’s range

It can set the gold karat’s high limit and low limit, like5K~24K6K~24K

9K~24K

Proportion parameter setup

It can set different proportion of copper and silver density7:36:45:5

Can set 7:3 only

Platinum

Display value

Platinum value and Density

Same

Pt’s range

It can set the platinum’s high limit and low limit, like1000Pt~600Pt1000Pt~500Pt

Same

Purity set

It can set platinum alloy different metal density parameter value

Same

Segment interface

RS-232

RS-232

Instrumentaccessories

Solid accessoriesThermometerTweezersCalibration weightAc adapterOperation manual

Solid accessories ThermometerTweezersCalibration weightAc adapterOperation manual

Marker

Jentest

Made In China

Mirage

Made In Japan


Comparison betweenMK-1500 & GK-2000

MODEL

Specification

MK-1500

GK-2000

Maximum weighing

1500g

2000g

Measurable range

10~1500g

10~2000g

Weighing precision

0.02/0.05g

0.01g

Average weight

0.001g

No

S.G. precision

0.001 g/cm3

 0.01 g/cm3

Water temperature compensate setup

Yes

Yes

Solution compensate setup

Yes

Yes

Gold

Display value

Karat  DensityPt

KaratDensity Pt

Karat’s range

It can set the gold karat’s high limit and low limit, like5K~24K6K~24K

9K~24K

Proportion parameter setup

It can set different proportion of copper and silver density7:36:45:5

Can set 7:3 only

Platinum

Display value

Platinum value and Density

Same

Pt’s range

It can set the platinum’s high limit and low limit, like1000Pt~600Pt1000Pt~500Pt

Same

Purity set

It can set platinum alloy different metal density parameter value

Same

Segment interface

RS-232

RS-232

Instrumentaccessories

Solid accessoriesThermometerTweezersCalibration weightAc adapterOperation manual

Solid accessories ThermometerTweezersCalibration weightAc adapterOperation manual

Marker

Jentest

Made In China

Mirage

Made In Japan

 

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!



HOME    INTRODUCES    PRODUCT    NEWS    TECHNOLOGY    CASES    MATERIAL    HONNER    RETAIN    CONTACT US
Dongguan Jen Test Equipment Co., Ltd.
Copyright@ 2003-2024  Dongguan Jen Test Equipment Co., Ltd.Copyright     
ADD: Tangli Road, Tutang First industrial Zone, Changping Town, Dongguan City,  Guangdong Province,China
  fromResponsible for network promotion        粤ICP备09054376号